5000A: 1A High Current Transformer Lo-Mc120II
Port:
Shanghai, China
Production Capacity:
60000PCS/Year
Payment Terms:
T/T, Western Union
Wuxi Liou Electronics Co., Ltd.
Jiangsu, China
Last Login Date:
Feb 24, 2025
Business Type:
Manufacturer/Factory, Trading Company
Main Products:
Current Transformer, Planartransformer, DC Immune Current Transformer, Micro Current Transformer, High Frequency Current Transformer, DC Pulse Current Transformer, Center Through Current Transformer, Split Core Current Transformer, Three-Phase Current Transformer, Voltage Transformer
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
LO-MC120II
Type
Electromagnetic
Output Signal Type
Analog Output
Production Process
Case
Material
Silicon Steel
Accuracy Grade
0.5G
Application
Electricity
IP Rating
IP20
Certification
RoHS
Customized
Non-Customized
Phase
Safety Standard
IEC60044-1
Thermal Class
Class B
Case Material
PC
Flame Retardant
UL94V-0
Packaging
Carton
Trademark
Liou
Transport Package
UPS, TNT, Federal Express, Ocean
Origin
China
HS Code
8504311000
Product Description
Center through current transformers
Description
The range of LiOu Instruments MC-II current transformers offers wide system current ratings, apertures, bus bar and case sizes to suit every application. Manufactured to meet EN60044 the range benefits include ratio rating from 100A to 6000A, accuracy up to Class 0.5, integral terminal cover for safety and multiple mounting options.
Mechanical Specifications:
Application
• Data logging • Recording • Power monitoring
• Energy management • Alternative energy monitoring
• Cost allocation
Features
• Frequency Range: 50-60Hz
• Over Load withstand: 1.2 x rated current continuously
• AC isolation resistance: 3KV for 60s
• Rigid housing case with UL® 94V-0 polycarbonate
• Safety standard: IEC/EN60044-1
• Nominal phase angle error and
Nominal linearity error: Conform IEC61869-2
ConformIEC60044-1
• Max. operation voltage: AC660V
• Thermal Insulation Class: Class B
• IP Protection Class: IP20B
• Humidity: Up to 95%RH (Non-condensing)
ELECTRIC SPECIFICAITON:
INSTALLAITON:
Description
The range of LiOu Instruments MC-II current transformers offers wide system current ratings, apertures, bus bar and case sizes to suit every application. Manufactured to meet EN60044 the range benefits include ratio rating from 100A to 6000A, accuracy up to Class 0.5, integral terminal cover for safety and multiple mounting options.
Mechanical Specifications:
P/N | DIMENSIONS | |||||
L1 | L2 | L3 | H1 | H2 | B1 | |
LO-MC40II | 45 | 42 | 75 | 31 | 88 | 45 |
LO-MC50II | 55 | 52 | 87 | 31 | 90 | 46 |
LO-MC60II | 42 | 62 | 99 | 31 | 95 | 46 |
LO-MC80II | 60 | 82 | 118 | 32 | 103 | 45 |
LO-MC100II | 75 | 102 | 141 | 33 | 107 | 49 |
LO-MC120II | 54 | 122 | 167 | 52 | 138 | 48 |
LO-MC140II | 54 | 142 | 187 | 35 | 116 | 48 |
LO-MC160II | 200 | 172 | 244 | 108 | 199 | 59 |
LO-MC180II | 185 | 182 | 228 | 35 | 100 | 48 |
Application
• Data logging • Recording • Power monitoring
• Energy management • Alternative energy monitoring
• Cost allocation
Features
• Frequency Range: 50-60Hz
• Over Load withstand: 1.2 x rated current continuously
• AC isolation resistance: 3KV for 60s
• Rigid housing case with UL® 94V-0 polycarbonate
• Safety standard: IEC/EN60044-1
• Nominal phase angle error and
Nominal linearity error: Conform IEC61869-2
ConformIEC60044-1
• Max. operation voltage: AC660V
• Thermal Insulation Class: Class B
• IP Protection Class: IP20B
• Humidity: Up to 95%RH (Non-condensing)
ELECTRIC SPECIFICAITON:
PART NUMBER | LO-MC40II | LO-MC 50II | LO-MC60II | LO-MC 80II | LO-MC100II | LO-MC120II | |||||||
Bus bar Spec(mm) | 40*10 1-2Pcs | 50*10 1-2Pcs | 60*10 1-2Pcs | 80*10 1-2Pcs | 100*10 1-2Pcs | 120*10 1-3Pcs | |||||||
Accuracy Class | 0.5 | 1 | 0.5 | 1 | 0.5 | 1 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | |
Current Ratio | Primary Turns | Rated Capacity(VA) | |||||||||||
100 5 | 1 | - | 2.5 | 2.5 | 2.5 | - | - | - | - | - | - | - | - |
150 5 | 1 | 2.5 | 2.5 | 2.5 | 2.5 | - | 2.5 | - | - | - | - | - | - |
200 5 | 1 | 5 | 5 | 2.5 | 5 | 2.5 | 5 | - | - | - | - | - | - |
250 5 | 1 | 5 | 5 | 2.5 | 5 | 2.5 | 5 | - | - | - | - | - | - |
300 5 | 1 | 5 | - | 5 | - | 5 | - | - | - | - | - | - | - |
400 5 | 1 | 10 | 10 | 10 | - | 10 | - | - | 5 | - | - | - | - |
500 5 | 1 | 10 | - | 10 | - | 10 | - | - | 10 | - | - | - | - |
600 5 | 1 | 10 | - | 10 | - | 10 | - | - | 10 | - | 10 | - | - |
800 5 | 1 | 10 | - | 10 | - | 10 | - | - | 10 | - | 10 | - | 10 |
1000 5 | 1 | 10 | 10 | - | 10 | - | 10 | - | 10 | ||||
1200/5 | 1 | 15 | 10 | 15 | 10 | 15 | 15 | 15 | |||||
1500 5 | 1 | 20 | 10 | 20 | 10 | 20 | 15 | 20 | |||||
2000 5 | 1 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |||||
2500 5 | 1 | 20 | 20 | 20 | 40 | 20 | 40 | ||||||
3000 5 | 1 | 20 | 40 | 20 | 40 | ||||||||
4000 5 | 1 | 40 | 40 | 40 | 40 | ||||||||
5000 5 | 1 | 40 | 40 | 40 | 40 | ||||||||
6000 5 | 1 | 40 | 40 | ||||||||||
50 1 | 1 | 0.1 | 0.2 | - | - | - | - | - | - | - | |||
60 1 | 1 | 0.1 | 0.2 | - | - | - | - | - | - | - | |||
75 1 | 1 | 0.2 | 1 | 0.2 | 0.2 | - | - | - | - | - | |||
100 1 | 1 | 0.4 | 2.5 | 0.2 | 0.2 | - | - | - | - | - | |||
150 1 | 1 | 2.5 | 2.5 | 0.4 | 0.4 | - | - | - | - | - | |||
200 1 | 1 | 2.5 | 2.5 | 2.5 | - | - | - | - | - | ||||
300 1 | 1 | 5 | 5 | 5 | 5 | - | 5 | - | 5 | ||||
400 1 | 1 | 5 | 5 | 5 | 5 | - | 5 | - | 5 | ||||
500 1 | 1 | 10 | 10 | 10 | 10 | - | 10 | - | 10 | ||||
600 1 | 1 | 10 | 10 | 10 | 10 | - | 10 | - | 10 | ||||
800 1 | 1 | 10 | 10 | 10 | 10 | - | 10 | - | 10 | ||||
1000 1 | 1 | 10 | 10 | 15 | - | 15 | - | 15 | |||||
1500 1 | 1 | 15 | 15 | 10 | 15 | 10 | 15 | ||||||
2000 1 | 1 | 20 | 15 | 20 | 15 | 20 | |||||||
3000 1 | 1 | 20 | 40 | 20 | 40 | ||||||||
4000 1 | 1 | 20 | 40 | ||||||||||
5000 1 | 1 | 20 | 40 |
ABSOLUTE MAXIMUM RATINGS | |
Operating free air temperature range | -20ºC to 65ºC |
Storage temperature range | -20ºC to 85ºC |
INSTALLAITON: